🏢🇨🇦WELL v2 Feature 74 · Global

Open Plan Office Acoustic Design in CanadaWELL v2 Feature 74 Requirements

Open plan workspaces, trading floors, collaborative offices. Typical volume: 500-5,000 m².

RT60 Target
≤ 0.5s
Background Noise
≤ 45 dBA
STI Requirement
< 0.50
Regulation
WELL v2 Feature 74
RT60 (Reverberation Time)
The time, in seconds, for sound to decay by 60 dB after the source stops. WELL v2 Feature 74 requires ≤ 0.5s for open plan office spaces in Canada.
Reference: WELL v2 Feature 74

What WELL v2 Feature 74 Requires for a Open Plan Office in Canada

Regulation: WELL v2 Feature 74

RT60 target: ≤ 0.5s

Background noise limit: ≤ 45 dBA

STI requirement: < 0.50

Local note: Toronto and Vancouver lead Canadian WELL-certified office market.

How to Calculate WELL v2 Feature 74 Compliance for a Open Plan Office in Canada

  1. 1

    Identify the applicable Canada standard and target

    Look up WELL v2 Feature 74 for open plan office spaces in Canada. The RT60 target is ≤ 0.5s. WELL v2 Feature 74.

  2. 2

    Measure or model the room geometry

    Record the length, width, and height of the room to calculate the volume. A typical open plan office has a volume of 500-5,000 m².

  3. 3

    List all surfaces and their absorption coefficients

    For each surface (floor, ceiling, walls, windows, doors), find the absorption coefficient at each octave band frequency (125 Hz to 4 kHz) from ISO 354 test data or a materials database.

  4. 4

    Calculate total absorption and apply the Sabine or Eyring equation

    Sum all surface absorption values: A = sum of (alpha x area). Then apply T60 = 0.161 x V / A (Sabine) or T60 = -0.161 x V / (S x ln(1 - alpha_avg)) (Eyring). Use Eyring when average alpha exceeds 0.20.

  5. 5

    Compare result against WELL v2 Feature 74 and specify treatment

    If the calculated RT60 exceeds the target of ≤ 0.5s, specify additional absorption. Typical treatment cost in Canada is C$100–C$180/m².

Cost of Compliance in Canada

Treatment Cost Range

C$100–C$180/m²

Currency: C$

What Affects Cost

  • • Room volume and surface area
  • • Target standard strictness
  • • Existing acoustic conditions
  • • Finish and material quality

Frequently Asked Questions

What RT60 does WELL v2 Feature 74 require for a open plan office in Canada?

WELL v2 Feature 74 requires a reverberation time of ≤ 0.5s for open plan office spaces in Canada. WELL v2 Feature 74. Measurement should be performed per ISO 3382-2 methodology.

What is the background noise limit for a open plan office in Canada?

The background noise limit is ≤ 45 dBA under WELL v2 Feature 74. This typically refers to HVAC and building services noise measured with the room unoccupied.

How much does acoustic treatment cost for a open plan office in Canada?

Typical acoustic treatment for a open plan office in Canada costs C$100–C$180/m². Costs vary based on finish quality, room size, and existing conditions.

Calculate WELL v2 Feature 74 Compliance for Your Open Plan Office in Canada

Enter your room dimensions, select materials, and instantly verify compliance against WELL v2 Feature 74. Free, no signup required.

Open Free RT60 Calculator