🏫🇫🇷NRA 2000 · France

Classroom Acoustic Design in FranceNRA 2000 Requirements

Primary and secondary school classrooms, lecture rooms. Typical volume: 150-300 m³.

RT60 Target
≤ 0.6s
Background Noise
≤ 35 dBA
STI Requirement
Not specified
Regulation
Arrêté du 25 avril 2003
RT60 (Reverberation Time)
The time, in seconds, for sound to decay by 60 dB after the source stops. NRA 2000 requires ≤ 0.6s for classroom spaces in France.
Reference: Arrêté du 25 avril 2003 — ERP acoustics

What NRA 2000 Requires for a Classroom in France

Regulation: Arrêté du 25 avril 2003 — ERP acoustics

RT60 target: ≤ 0.6s

Background noise limit: ≤ 35 dBA

Local note: French education buildings (ERP) have specific RT60 targets by room type.

How to Calculate NRA 2000 Compliance for a Classroom in France

  1. 1

    Identify the applicable France standard and target

    Look up NRA 2000 for classroom spaces in France. The RT60 target is ≤ 0.6s. Arrêté du 25 avril 2003 — ERP acoustics.

  2. 2

    Measure or model the room geometry

    Record the length, width, and height of the room to calculate the volume. A typical classroom has a volume of 150-300 m³.

  3. 3

    List all surfaces and their absorption coefficients

    For each surface (floor, ceiling, walls, windows, doors), find the absorption coefficient at each octave band frequency (125 Hz to 4 kHz) from ISO 354 test data or a materials database.

  4. 4

    Calculate total absorption and apply the Sabine or Eyring equation

    Sum all surface absorption values: A = sum of (alpha x area). Then apply T60 = 0.161 x V / A (Sabine) or T60 = -0.161 x V / (S x ln(1 - alpha_avg)) (Eyring). Use Eyring when average alpha exceeds 0.20.

  5. 5

    Compare result against NRA 2000 and specify treatment

    If the calculated RT60 exceeds the target of ≤ 0.6s, specify additional absorption. Typical treatment cost in France is €17,000–€25,000.

Cost of Compliance in France

Treatment Cost Range

€17,000–€25,000

Currency:

What Affects Cost

  • • Room volume and surface area
  • • Target standard strictness
  • • Existing acoustic conditions
  • • Finish and material quality

Frequently Asked Questions

What RT60 does NRA 2000 require for a classroom in France?

NRA 2000 requires a reverberation time of ≤ 0.6s for classroom spaces in France. Arrêté du 25 avril 2003 — ERP acoustics. Measurement should be performed per ISO 3382-2 methodology.

What is the background noise limit for a classroom in France?

The background noise limit is ≤ 35 dBA under NRA 2000. This typically refers to HVAC and building services noise measured with the room unoccupied.

How much does acoustic treatment cost for a classroom in France?

Typical acoustic treatment for a classroom in France costs €17,000–€25,000. Costs vary based on finish quality, room size, and existing conditions.

Calculate NRA 2000 Compliance for Your Classroom in France

Enter your room dimensions, select materials, and instantly verify compliance against NRA 2000. Free, no signup required.

Open Free RT60 Calculator