🏥🇫🇷NRA 2000 · France

Hospital Ward Acoustic Design in FranceNRA 2000 Requirements

Patient wards, recovery rooms, consultation rooms. Typical volume: 100-500 m³.

RT60 Target
≤ 0.8s
Background Noise
≤ 40 dBA
STI Requirement
N/A
Regulation
NRA + HQE Santé
RT60 (Reverberation Time)
The time, in seconds, for sound to decay by 60 dB after the source stops. NRA 2000 requires ≤ 0.8s for hospital ward spaces in France.
Reference: NRA + HQE Santé

What NRA 2000 Requires for a Hospital Ward in France

Regulation: NRA + HQE Santé

RT60 target: ≤ 0.8s

Background noise limit: ≤ 40 dBA

Local note: French hospitals must meet NRA plus HQE Santé acoustic criteria.

How to Calculate NRA 2000 Compliance for a Hospital Ward in France

  1. 1

    Identify the applicable France standard and target

    Look up NRA 2000 for hospital ward spaces in France. The RT60 target is ≤ 0.8s. NRA + HQE Santé.

  2. 2

    Measure or model the room geometry

    Record the length, width, and height of the room to calculate the volume. A typical hospital ward has a volume of 100-500 m³.

  3. 3

    List all surfaces and their absorption coefficients

    For each surface (floor, ceiling, walls, windows, doors), find the absorption coefficient at each octave band frequency (125 Hz to 4 kHz) from ISO 354 test data or a materials database.

  4. 4

    Calculate total absorption and apply the Sabine or Eyring equation

    Sum all surface absorption values: A = sum of (alpha x area). Then apply T60 = 0.161 x V / A (Sabine) or T60 = -0.161 x V / (S x ln(1 - alpha_avg)) (Eyring). Use Eyring when average alpha exceeds 0.20.

  5. 5

    Compare result against NRA 2000 and specify treatment

    If the calculated RT60 exceeds the target of ≤ 0.8s, specify additional absorption. Typical treatment cost in France is €22,000–€36,000 per 100m².

Cost of Compliance in France

Treatment Cost Range

€22,000–€36,000 per 100m²

Currency:

What Affects Cost

  • • Room volume and surface area
  • • Target standard strictness
  • • Existing acoustic conditions
  • • Finish and material quality

Frequently Asked Questions

What RT60 does NRA 2000 require for a hospital ward in France?

NRA 2000 requires a reverberation time of ≤ 0.8s for hospital ward spaces in France. NRA + HQE Santé. Measurement should be performed per ISO 3382-2 methodology.

What is the background noise limit for a hospital ward in France?

The background noise limit is ≤ 40 dBA under NRA 2000. This typically refers to HVAC and building services noise measured with the room unoccupied.

How much does acoustic treatment cost for a hospital ward in France?

Typical acoustic treatment for a hospital ward in France costs €22,000–€36,000 per 100m². Costs vary based on finish quality, room size, and existing conditions.

Calculate NRA 2000 Compliance for Your Hospital Ward in France

Enter your room dimensions, select materials, and instantly verify compliance against NRA 2000. Free, no signup required.

Open Free RT60 Calculator