🏫🇩🇪WELL v2 Feature 74 · Global

Classroom Acoustic Design in GermanyWELL v2 Feature 74 Requirements

Primary and secondary school classrooms, lecture rooms. Typical volume: 150-300 m³.

RT60 Target
≤ 0.6s
Background Noise
≤ 35 dBA
STI Requirement
≥ 0.60
Regulation
WELL v2 Feature 74
RT60 (Reverberation Time)
The time, in seconds, for sound to decay by 60 dB after the source stops. WELL v2 Feature 74 requires ≤ 0.6s for classroom spaces in Germany.
Reference: WELL v2 Feature 74

What WELL v2 Feature 74 Requires for a Classroom in Germany

Regulation: WELL v2 Feature 74

RT60 target: ≤ 0.6s

Background noise limit: ≤ 35 dBA

STI requirement: ≥ 0.60

Local note: WELL gaining traction in German international school projects.

How to Calculate WELL v2 Feature 74 Compliance for a Classroom in Germany

  1. 1

    Identify the applicable Germany standard and target

    Look up WELL v2 Feature 74 for classroom spaces in Germany. The RT60 target is ≤ 0.6s. WELL v2 Feature 74.

  2. 2

    Measure or model the room geometry

    Record the length, width, and height of the room to calculate the volume. A typical classroom has a volume of 150-300 m³.

  3. 3

    List all surfaces and their absorption coefficients

    For each surface (floor, ceiling, walls, windows, doors), find the absorption coefficient at each octave band frequency (125 Hz to 4 kHz) from ISO 354 test data or a materials database.

  4. 4

    Calculate total absorption and apply the Sabine or Eyring equation

    Sum all surface absorption values: A = sum of (alpha x area). Then apply T60 = 0.161 x V / A (Sabine) or T60 = -0.161 x V / (S x ln(1 - alpha_avg)) (Eyring). Use Eyring when average alpha exceeds 0.20.

  5. 5

    Compare result against WELL v2 Feature 74 and specify treatment

    If the calculated RT60 exceeds the target of ≤ 0.6s, specify additional absorption. Typical treatment cost in Germany is €22,000–€32,000.

Cost of Compliance in Germany

Treatment Cost Range

€22,000–€32,000

Currency:

What Affects Cost

  • • Room volume and surface area
  • • Target standard strictness
  • • Existing acoustic conditions
  • • Finish and material quality

How WELL v2 Feature 74 Differs from Other Standards for Classroom in Germany

RequirementWELL v2 Feature 74DIN 18041:2016
RT60 Target≤ 0.6s≤ 0.55s (Class A)
Background Noise≤ 35 dBA≤ 35 dBA
STI≥ 0.60≥ 0.65
Cost Range€22,000–€32,000€19,000–€28,000 per classroom

Frequently Asked Questions

What RT60 does WELL v2 Feature 74 require for a classroom in Germany?

WELL v2 Feature 74 requires a reverberation time of ≤ 0.6s for classroom spaces in Germany. WELL v2 Feature 74. Measurement should be performed per ISO 3382-2 methodology.

What is the background noise limit for a classroom in Germany?

The background noise limit is ≤ 35 dBA under WELL v2 Feature 74. This typically refers to HVAC and building services noise measured with the room unoccupied.

How much does acoustic treatment cost for a classroom in Germany?

Typical acoustic treatment for a classroom in Germany costs €22,000–€32,000. Costs vary based on finish quality, room size, and existing conditions.

Calculate WELL v2 Feature 74 Compliance for Your Classroom in Germany

Enter your room dimensions, select materials, and instantly verify compliance against WELL v2 Feature 74. Free, no signup required.

Open Free RT60 Calculator