Meeting Room Acoustic Design in United Arab Emirates — WELL v2 Feature 74 Requirements
Conference rooms, boardrooms, video conferencing spaces. Typical volume: 30-150 m³.
What WELL v2 Feature 74 Requires for a Meeting Room in United Arab Emirates
Regulation: WELL v2 Feature 74 Part 1
RT60 target: ≤ 0.6s
Background noise limit: ≤ 35 dBA
STI requirement: ≥ 0.60
How to Calculate WELL v2 Feature 74 Compliance for a Meeting Room in United Arab Emirates
- 1
Identify the applicable United Arab Emirates standard and target
Look up WELL v2 Feature 74 for meeting room spaces in United Arab Emirates. The RT60 target is ≤ 0.6s. WELL v2 Feature 74 Part 1.
- 2
Measure or model the room geometry
Record the length, width, and height of the room to calculate the volume. A typical meeting room has a volume of 30-150 m³.
- 3
List all surfaces and their absorption coefficients
For each surface (floor, ceiling, walls, windows, doors), find the absorption coefficient at each octave band frequency (125 Hz to 4 kHz) from ISO 354 test data or a materials database.
- 4
Calculate total absorption and apply the Sabine or Eyring equation
Sum all surface absorption values: A = sum of (alpha x area). Then apply T60 = 0.161 x V / A (Sabine) or T60 = -0.161 x V / (S x ln(1 - alpha_avg)) (Eyring). Use Eyring when average alpha exceeds 0.20.
- 5
Compare result against WELL v2 Feature 74 and specify treatment
If the calculated RT60 exceeds the target of ≤ 0.6s, specify additional absorption. Typical treatment cost in United Arab Emirates is AED 8,000–AED 18,000.
Cost of Compliance in United Arab Emirates
Treatment Cost Range
AED 8,000–AED 18,000
Currency: AED
What Affects Cost
- • Room volume and surface area
- • Target standard strictness
- • Existing acoustic conditions
- • Finish and material quality
Frequently Asked Questions
What RT60 does WELL v2 Feature 74 require for a meeting room in United Arab Emirates?
WELL v2 Feature 74 requires a reverberation time of ≤ 0.6s for meeting room spaces in United Arab Emirates. WELL v2 Feature 74 Part 1. Measurement should be performed per ISO 3382-2 methodology.
What is the background noise limit for a meeting room in United Arab Emirates?
The background noise limit is ≤ 35 dBA under WELL v2 Feature 74. This typically refers to HVAC and building services noise measured with the room unoccupied.
How much does acoustic treatment cost for a meeting room in United Arab Emirates?
Typical acoustic treatment for a meeting room in United Arab Emirates costs AED 8,000–AED 18,000. Costs vary based on finish quality, room size, and existing conditions.
Calculate WELL v2 Feature 74 Compliance for Your Meeting Room in United Arab Emirates
Enter your room dimensions, select materials, and instantly verify compliance against WELL v2 Feature 74. Free, no signup required.
Open Free RT60 Calculator