🍽️🇦🇪WELL v2 Feature 74 · Global

Restaurant Acoustic Design in United Arab EmiratesWELL v2 Feature 74 Requirements

Restaurants, cafes, bars, food halls. Typical volume: 200-2,000 m³.

RT60 Target
≤ 0.8s
Background Noise
40–50 dBA
STI Requirement
N/A
Regulation
WELL v2 for F&B within certified buildings
RT60 (Reverberation Time)
The time, in seconds, for sound to decay by 60 dB after the source stops. WELL v2 Feature 74 requires ≤ 0.8s for restaurant spaces in United Arab Emirates.
Reference: WELL v2 for F&B within certified buildings

What WELL v2 Feature 74 Requires for a Restaurant in United Arab Emirates

Regulation: WELL v2 for F&B within certified buildings

RT60 target: ≤ 0.8s

Background noise limit: 40–50 dBA

Local note: Dubai luxury dining market drives demand for premium acoustic design.

How to Calculate WELL v2 Feature 74 Compliance for a Restaurant in United Arab Emirates

  1. 1

    Identify the applicable United Arab Emirates standard and target

    Look up WELL v2 Feature 74 for restaurant spaces in United Arab Emirates. The RT60 target is ≤ 0.8s. WELL v2 for F&B within certified buildings.

  2. 2

    Measure or model the room geometry

    Record the length, width, and height of the room to calculate the volume. A typical restaurant has a volume of 200-2,000 m³.

  3. 3

    List all surfaces and their absorption coefficients

    For each surface (floor, ceiling, walls, windows, doors), find the absorption coefficient at each octave band frequency (125 Hz to 4 kHz) from ISO 354 test data or a materials database.

  4. 4

    Calculate total absorption and apply the Sabine or Eyring equation

    Sum all surface absorption values: A = sum of (alpha x area). Then apply T60 = 0.161 x V / A (Sabine) or T60 = -0.161 x V / (S x ln(1 - alpha_avg)) (Eyring). Use Eyring when average alpha exceeds 0.20.

  5. 5

    Compare result against WELL v2 Feature 74 and specify treatment

    If the calculated RT60 exceeds the target of ≤ 0.8s, specify additional absorption. Typical treatment cost in United Arab Emirates is AED 100–AED 200/m².

Cost of Compliance in United Arab Emirates

Treatment Cost Range

AED 100–AED 200/m²

Currency: AED

What Affects Cost

  • • Room volume and surface area
  • • Target standard strictness
  • • Existing acoustic conditions
  • • Finish and material quality

Frequently Asked Questions

What RT60 does WELL v2 Feature 74 require for a restaurant in United Arab Emirates?

WELL v2 Feature 74 requires a reverberation time of ≤ 0.8s for restaurant spaces in United Arab Emirates. WELL v2 for F&B within certified buildings. Measurement should be performed per ISO 3382-2 methodology.

What is the background noise limit for a restaurant in United Arab Emirates?

The background noise limit is 40–50 dBA under WELL v2 Feature 74. This typically refers to HVAC and building services noise measured with the room unoccupied.

How much does acoustic treatment cost for a restaurant in United Arab Emirates?

Typical acoustic treatment for a restaurant in United Arab Emirates costs AED 100–AED 200/m². Costs vary based on finish quality, room size, and existing conditions.

Calculate WELL v2 Feature 74 Compliance for Your Restaurant in United Arab Emirates

Enter your room dimensions, select materials, and instantly verify compliance against WELL v2 Feature 74. Free, no signup required.

Open Free RT60 Calculator

Related Pages