Articles tagged “modulation transfer function”
4 articles covering modulation transfer function in acoustic engineering and building design.
IEC 60268-16: Measuring Speech Intelligibility (STI/STIPA)
A practical guide to IEC 60268-16 speech intelligibility measurement — STI and STIPA methods explained, equipment requirements, field measurement procedures, and common interpretation errors.
How is STI Measured?
STI (Speech Transmission Index) is measured using modulation transfer functions derived from impulse responses or STIPA test signals. Learn the full-band and STIPA methods per IEC 60268-16.
Speech Transmission Index (STI) — The Complete Technical Reference
The definitive technical reference for STI (Speech Transmission Index) covering MTF theory, the full 98-point calculation method per IEC 60268-16:2020, STIPA and RASTI simplified methods, the CIS intelligibility scale, measurement equipment and methodology, STI targets by room type, and the relationship between RT60, background noise, and speech intelligibility.
IEC 60268-16 Complete Guide: Speech Transmission Index (STI) Standard
IEC 60268-16:2020 defines the Speech Transmission Index — the definitive metric for speech intelligibility in rooms. Here is every aspect of the standard explained: the STI calculation method, STIPA measurement procedure, quality scale, and how building codes worldwide use it.