Articles tagged “well v2 feature 74

7 articles covering well v2 feature 74 in acoustic engineering and building design.

📐
GUIDES14 min read

Free RT60 Calculator Online — No Signup, Instant ISO 3382 Results

Calculate reverberation time free online. ISO 3382-2 compliant. Sabine + Eyring equations. RT60 per octave band 125Hz–4kHz. WELL v2 Feature 74 compliance check included. No signup required.

March 14, 2026
free RT60 calculatoronline RT60 calculator
📐
GUIDES16 min read

Can Everyone Hear Your Calls? Why Open Office Speech Privacy Fails

If you can clearly understand a colleague's phone conversation from 4 metres away, your office STI is above 0.50 — and your speech privacy is non-existent. WELL v2 Feature 74 Part 3 requires STI < 0.50. Here is how to achieve it.

March 14, 2026
office speech privacyopen office privacy
📐
GUIDES19 min read

Why Your WELL Acoustic Certification Will Fail: The 5 Errors Most Architects Make

Five calculation errors that cause WELL v2 Feature 74 acoustic certifications to fail at assessment stage — each with the specific number that trips the design. Passing RT60 is necessary but not sufficient. Here is what WELL assessors actually check.

March 14, 2026
WELL certificationWELL v2 Feature 74
📐
GUIDES13 min read

Free WELL v2 Feature 74 Acoustic Calculator — Generate Your Compliance Report

Calculate WELL v2 Feature 74 acoustic compliance free. Parts 1, 2, and 3. RT60, background noise, and speech privacy (STI) checked simultaneously. Generate a WELL F74 compliance report in PDF format.

March 14, 2026
WELL F74 calculatorWELL acoustic calculator
📐
GUIDES17 min readFeatured

NRC 0.75 Does Not Mean 75% Absorption — Here Is What It Actually Means

NRC is an arithmetic average of four octave bands. A panel rated NRC 0.75 can have α = 0.40 at 250Hz — and that bass deficiency will make your meeting room fail its WELL F74 assessment at the exact frequency where speech intelligibility lives.

March 13, 2026
NRCabsorption coefficient
⚠️
INCIDENT19 min read

The School Nobody Could Learn In: What ANSI S12.60 Failures Cost Students

35% of UK classrooms fail BS 8233 acoustic targets. The reason is not RT60 — it is STI. Architects design for reverberation time and ignore the speech transmission index calculation that ANSI S12.60 and DIN 18041 actually require. This is what that costs.

March 13, 2026
classroomSTI
📋
STANDARDS23 min readFeatured

WELL v2 Feature 74 Decoded: Every Acoustic Requirement, Every Calculation, Every Clause

WELL Building Standard v2 Feature 74 has three parts with different requirements for RT60, background noise, and speech privacy. Most WELL assessors fail Part 3 because the speech privacy STI calculation is never written down in one place — until now.

March 13, 2026
WELL v2 Feature 74WELL certification