Skip to main content

Articles tagged “worked example

14 articles covering worked example in acoustic engineering and building design.

🎓
TUTORIALS10 min read

How to Calculate RT60 for an Open-Plan Office — Full Worked Example

Step-by-step Sabine RT60 calculation for a 300 m² open-plan office. Every surface area, absorption coefficient, and octave-band sum shown — from bare slab to treated space.

March 18, 2026
RT60 calculationopen plan office
🎓
TUTORIALS11 min read

How to Calculate STI for a Classroom — IEC 60268-16 Step-by-Step

Full STI calculation for a 200 m³ classroom. Derive RT60 via Sabine, then compute speech transmission index using the modulation transfer function method per IEC 60268-16:2020.

March 18, 2026
STI calculationclassroom
🎓
TUTORIALS9 min read

Ceiling Absorption Calculation: Octave-Band RT60 Prediction for 3 Ceiling Types

Same 200 m³ room, three ceiling systems: 15mm mineral fibre, 25mm perforated metal with backing, and 50mm exposed mineral wool. Full Sabine RT60 for each at 125–4000 Hz.

March 18, 2026
ceiling absorptionoctave band
🎓
TUTORIALS10 min read

Concert Hall RT60 Design: 1,800-Seat Auditorium Worked Example

Design an 1,800-seat concert hall for RT60 2.0 s (occupied). Full octave-band Sabine calculation, audience absorption, occupied vs unoccupied comparison, and EDT estimation.

March 18, 2026
concert hallRT60 design
🎓
TUTORIALS9 min read

Impact Noise Floor Build-Up: ΔLw Improvement Calculation — ISO 717-2

Start with bare 150mm concrete slab (L'nT,w 78 dB). Add resilient mat, screed, and carpet step by step. Calculate ΔLw at each stage per ISO 717-2 with full IIC ratings.

March 18, 2026
impact noisefloor buildup
🎓
TUTORIALS10 min read

NC Curve Calculation from Octave-Band Measurements — Step-by-Step

Determine the NC rating from a set of octave-band background noise measurements. Step-by-step tangent curve method, controlling frequency identification, and RC Mark II comparison.

March 18, 2026
NC curveHVAC noise
🎓
TUTORIALS9 min read

Facade Noise Break-In Calculation: External Noise to Internal Level — ISO 12354-3

70 dBA road traffic at facade: calculate internal noise through composite wall, window, and ventilator using ISO 12354-3. Area-weighted Rw and BS 8233 compliance check.

March 18, 2026
facade noisenoise break-in
🎓
TUTORIALS12 min read

Outdoor Noise Propagation Calculation: ISO 9613-2 Step-by-Step Example

Industrial source at 200m: calculate receiver level using ISO 9613-2. Geometrical divergence, atmospheric absorption, ground effect, and barrier attenuation — full octave-band worked example.

March 18, 2026
outdoor noiseISO 9613
🎓
TUTORIALS11 min read

Lab STC to Field FSTC: How to Predict Real-World Sound Insulation Performance

Take a lab STC 55 partition and predict field FSTC accounting for flanking paths: floor, ceiling plenum, ductwork, and outlets. Full ISO 15712 worked example.

March 18, 2026
STCFSTC
🎓
TUTORIALS11 min read

Restaurant Acoustic Treatment Calculation — From 2.1 s RT60 to Comfortable Dining

250 m² restaurant with 4 m ceilings and RT60 = 2.1 s. Calculate the absorption deficit and design a treatment scheme to reach 0.8 s — with full octave-band before/after comparison.

March 18, 2026
restaurant acousticsacoustic treatment
🎓
TUTORIALS10 min read

Sabine vs Eyring: Same Room, Different Answers — Worked Comparison

Calculate RT60 with both Sabine and Eyring equations for the same recording studio. See exactly where the results diverge, why, and when the 28% difference matters for design decisions.

March 18, 2026
Sabine equationEyring equation
🎓
TUTORIALS12 min read

Sound Masking System Design: Spectrum, Level, and Coverage Calculation

Design a sound masking system for a 500 m² open office from scratch: masking spectrum, required level, speaker spacing, and before/after Articulation Index.

March 18, 2026
sound maskingsystem design
🎓
TUTORIALS10 min read

Composite STC Calculation: Wall + Door + Window — Full Worked Example

Calculate composite STC for an office wall with a door and window. See how an STC 28 door drags down an STC 55 wall — with full area-weighted transmission loss at every 1/3 octave band.

March 18, 2026
STC calculationcomposite wall
🎓
TUTORIALS13 min read

WELL v2 Feature 74 Compliance: Full Acoustic Calculation for a 3-Storey Office

Full WELL v2 Feature 74 compliance check for a 3-storey office: Sound Mapping (L01), STC requirements (L03), Background Noise (L05), and RT60 (L07) with detailed calculations.

March 18, 2026
WELL v2Feature 74