Corporate Offices & Co-Working Acoustic Design Guide

Modern offices must balance speech privacy in open-plan layouts with intelligibility in meeting rooms, while achieving WELL v2 Feature 74 certification. Open-plan acoustic design focuses on spatial de...

WELL v2 Feature 74BS 8233:2014LEED v4.1 EQ CreditISO 3382-3:2012

Key Challenge

Achieving speech privacy in open-plan areas (STI < 0.50 beyond distraction distance) while maintaini...

Typical Budget

0.8–1.5% of fit-out cost

Primary Standard

WELL v2 Feature 74

Room-by-Room Requirements

Acoustic targets for each room type within corporate offices & co-working buildings.

RoomRT60 TargetKey Metric
Open-Plan OfficerD < 5 mSTI < 0.50 at 8mDetails →
Meeting Room≤0.6sSTC 45+Details →
Phone Booth≤0.4sSTC 35+Details →
Reception≤0.8sSTI ≥0.55Details →
Office Canteen≤1.0sLAeq ≤45 dBDetails →

Applicable Standards

The following standards govern acoustic performance for corporate offices & co-working buildings.

1.

WELL v2 Feature 74

2.

BS 8233:2014

3.

LEED v4.1 EQ Credit

4.

ISO 3382-3:2012

Green Certifications

Voluntary certifications that include acoustic performance credits for corporate offices & co-working projects.

WELL v2 Sound

LEED EQ Credit

BREEAM Hea 05

Fitwel

Frequently Asked Questions: Corporate Offices & Co-Working

What is the distraction distance in open-plan offices?
Distraction distance (rD) is defined in ISO 3382-3 as the distance from a speaker at which the STI drops below 0.50, meaning speech becomes unintelligible. WELL v2 Feature 74 requires rD < 5 metres for open-plan offices. Achieving this requires a combination of absorptive ceilings, desk screens, and sound masking systems.
How does WELL v2 Feature 74 affect office acoustic design?
WELL v2 Feature 74 (Sound) sets prescriptive thresholds for background noise levels (NR 35–40), reverberation time (≤0.6s in enclosed rooms), sound masking levels (45–48 dBA), and speech privacy metrics. Compliance requires third-party commissioning measurements and is increasingly demanded by premium office tenants.
What is the recommended STC rating between office meeting rooms?
Meeting rooms handling confidential discussions should achieve STC 50 or higher between adjacent rooms. Standard meeting rooms require a minimum STC 45. The partition must extend from slab to slab, not just to the suspended ceiling, to prevent flanking transmission through the ceiling plenum.

Design Your Corporate Offices & Co-Working Acoustics

Enter your room dimensions, select materials, and instantly verify compliance against WELL v2 Feature 74. Free, no signup required.

Open Free Calculator