Open Plan Office Acoustic Requirements

Open plan workspaces, trading floors, collaborative offices. Typical volume: 500-5,000 m². Covered by 2 acoustic standards.

RT60 (Reverberation Time)
The time, in seconds, for a sound to decay by 60 decibels after the source stops. Measured per ISO 3382-2:2008 at octave band centre frequencies from 125 Hz to 4 kHz.
Reference: ISO 3382-2:2008 \u00A73.1

Standards Comparison for Open Plan Office

StandardRT60 TargetBackground NoiseSTI Target
GlobalWELL v2 Feature 74≤ 0.5s (meeting rooms within) | open plan: distraction distance rD < 5m≤ 45 dBA (open plan) | ≤ 35 dBA (HVAC mechanical)STI < 0.50 between workstations (speech privacy)
UKBS 8233:2014≤ 0.8s (large open offices)35-40 dBA (ambient)Not specified

Detailed Requirements by Standard

Frequently Asked Questions

What RT60 does a open plan office need?

RT60 targets vary by standard. WELL v2 Feature 74 requires ≤ 0.5s (meeting rooms within) | open plan: distraction distance rD < 5m. BS 8233:2014 requires ≤ 0.8s (large open offices).

Which acoustic standard applies to open plan office spaces?

The applicable standard depends on region and certification: WELL v2 Feature 74 (Global), BS 8233:2014 (UK).

How much does acoustic treatment cost for a open plan office?

Costs vary by standard and treatment scope. WELL v2 Feature 74: AUD 130-220/m² of floor area installed. BS 8233:2014: £85-£140/m² of floor area installed.