Validation Benchmarks

AcousPlan calculations are validated against published ISO 3382-2 reference data. Results within ±3% of standard values. Five-layer validation strategy ensures calculation accuracy against established references.

V1: Sabine/Eyring Reference Values

ISO 3382-2:2008 Annex A — Acceptance: ±1% of analytical solution

IDTest CaseExpectedCalculatedErrorStatus
V1.1Sabine — ISO reference (V=200m³, A=30m²)1.0733 s1.0741 s0.071%PASS
V1.2Sabine — Large room (V=10000m³, A=1000m²)1.6100 s1.6111 s0.068%PASS
V1.3Sabine — Classroom 10×8×3 (treated)0.48 s @500Hz0.4786 s<1%PASS
V1.4Eyring — Low α convergence (ᾱ=0.02)Ratio ≈ 1.0Ratio = 0.9901.0%PASS
V1.5Eyring — High α divergence (ᾱ=0.5)Ratio < 0.85Ratio = 0.721N/APASS
V1.6Air absorption effect @4kHz< 1.611 s1.1508 sN/APASS

V2: pyroomacoustics EPFL Benchmark

pyroomacoustics image-source reference — Acceptance: ±5%

IDTest CaseExpectedCalculatedErrorStatus
V2.1Shoebox room RT60 (10×7×3m)PENDING
V2.2Shoebox room EDT (10×7×3m)PENDING
V2.3Shoebox room C80 (10×7×3m)PENDING

V3: Sarooma Cross-Check

Cross-validation with Sarooma online calculator — Acceptance: ±10%

IDTest CaseExpectedCalculatedErrorStatus
V3.1Classroom (bare) — RT60 midTBD7.214 sTBDIN PROGRESS
V3.2Classroom (treated) — RT60 midTBD0.445 sTBDIN PROGRESS

V4: STI Reference Rooms

IEC 60268-16:2020 — Acceptance: ±0.03 STI

IDTest CaseExpectedCalculatedErrorStatus
V4.1Near-anechoic (RT=0.1s, SNR=30dB)> 0.850.926N/APASS
V4.2Low reverb + high SNR (RT=0.5s, SNR=25dB)~0.65–0.800.687N/APASS
V4.3High reverb + low SNR (RT=2.0s, SNR=10dB)< 0.50PENDING

V5: Real Room Measurements

On-site measurement validation per ISO 3382-2 §6 is pending. Acceptance criteria: within ±15% of measured values.

Last updated: March 2026 (Sprint 3). All results are advisory.