Meeting Room Acoustic Requirements
Conference rooms, boardrooms, video conferencing spaces. Typical volume: 30-150 m³. Covered by 2 acoustic standards.
Standards Comparison for Meeting Room
| Standard | RT60 Target | Background Noise | STI Target |
|---|---|---|---|
| GlobalWELL v2 Feature 74 | ≤ 0.6s | ≤ 35 dBA | ≥ 0.60 |
| UKBS 8233:2014 | ≤ 0.6s | ≤ 35 dBA | Not specified |
Detailed Requirements by Standard
Frequently Asked Questions
What RT60 does a meeting room need?
RT60 targets vary by standard. WELL v2 Feature 74 requires ≤ 0.6s. BS 8233:2014 requires ≤ 0.6s.
Which acoustic standard applies to meeting room spaces?
The applicable standard depends on region and certification: WELL v2 Feature 74 (Global), BS 8233:2014 (UK).
How much does acoustic treatment cost for a meeting room?
Costs vary by standard and treatment scope. WELL v2 Feature 74: £4,000-£9,000 installed. BS 8233:2014: £3,500-£7,000 installed.
Verify Compliance for Your Meeting Room
Enter your room dimensions and materials. AcousPlan calculates RT60 against all applicable standards instantly.
Open Free RT60 Calculator