Conference rooms, boardrooms, video conferencing spaces. Typical volume: 30-150 m³.

RT60 Target
≤ 0.6s
Background Noise
≤ 35 dBA
STI Target
≥ 0.60
Measurement
Furnished

What WELL v2 Feature 74 Requires for a Meeting Room

RT60 (Reverberation Time)
The time, in seconds, for sound to decay by 60 dB after the source stops. WELL v2 Feature 74 requires ≤ 0.6s for meeting room spaces.
Reference: WELL v2 Feature 74 Part 1 Precondition 1

Clause reference: WELL v2 Feature 74 Part 1 Precondition 1

RT60 target: ≤ 0.6s

STI target: ≥ 0.60

Background noise limit: ≤ 35 dBA

Measurement condition: Furnished

Note: Most commonly required WELL acoustic credit

How to Calculate WELL v2 Feature 74 Compliance for a Meeting Room

  1. 1

    Identify the applicable standard and target

    Look up WELL v2 Feature 74 (WELL v2 Feature 74 Part 1 Precondition 1). For a meeting room, the RT60 target is ≤ 0.6s. Measurement condition: furnished.

  2. 2

    Measure or model the room geometry

    Record the length, width, and height of the room to calculate the volume. A typical meeting room has a volume of 30-150 m³.

  3. 3

    List all surfaces and their absorption coefficients

    For each surface (floor, ceiling, walls, windows, doors), find the absorption coefficient at each octave band frequency (125Hz to 4kHz) from ISO 354 test data or a materials database.

  4. 4

    Calculate total absorption and apply the Sabine or Eyring equation

    Sum all surface absorption values: A = sum of (alpha x area). Then apply T60 = 0.161 x V / A (Sabine) or T60 = -0.161 x V / (S x ln(1 - alpha_avg)) (Eyring). Use Eyring when average alpha exceeds 0.20.

  5. 5

    Compare result against the standard and specify treatment if needed

    If the calculated RT60 exceeds the target of ≤ 0.6s, specify additional absorption. 12-20 m² ceiling panels is typical for a meeting room to achieve compliance.

Typical Acoustic Treatment for a Meeting Room

Treatment Area

12-20 m² ceiling panels

Estimated Cost

£4,000-£9,000 installed

Meeting Room: WELL v2 Feature 74 vs Other Standards

RequirementWELL v2 Feature 74BS 8233:2014
RT60 Target≤ 0.6s≤ 0.6s
STI Target≥ 0.60Not specified
Background Noise≤ 35 dBA≤ 35 dBA
MeasurementFurnishedFurnished

Frequently Asked Questions

What RT60 does WELL v2 Feature 74 require for a meeting room?

WELL v2 Feature 74 (WELL v2 Feature 74 Part 1 Precondition 1) requires a reverberation time of ≤ 0.6s for meeting room spaces, measured in the furnished condition per ISO 3382-2.

What background noise level is acceptable in a meeting room under WELL v2 Feature 74?

WELL v2 Feature 74 sets a background noise limit of ≤ 35 dBA for meeting room spaces. This typically refers to HVAC and building services noise measured with the room unoccupied.

How much acoustic treatment does a meeting room need to comply with WELL v2 Feature 74?

A typical meeting room requires 12-20 m² ceiling panels of acoustic treatment to meet WELL v2 Feature 74 compliance. Estimated installed cost is £4,000-£9,000 installed.

Calculate WELL v2 Feature 74 Compliance for Your Meeting Room

Enter your room dimensions, select materials, and instantly verify compliance against WELL v2 Feature 74. Free, no signup required.

Open Free RT60 Calculator

Related